Effectively removes moisture from compressed air with high efficiency and reliable performance. A compact, durable and energy-saving solution for industrial applications.
150 m³/h
16 bar
+3°C
Expanding its portfolio of innovative compressed air solutions, Separon introduces the SED Series, setting a new standard in refrigerated drying technology. Designed for maximum efficiency and environmentally friendly operation, these models run on an eco-friendly refrigerant with low global warming potential.
Delivering reliable performance across a wide range of operating conditions, the SED Series effectively removes moisture from the system with precise dew point control. Its design, focused on sustainability and easy maintenance, minimizes energy consumption while delivering high performance even in demanding industrial conditions.
Take a closer look at the main components of the SED series and their functions.

1234567Full capacity and performance table for SED series models
| Model | Capacity (Nm³/min) | Connection Size | Voltage (V/Ph/Hz) | Max. Working Pressure | Filter Model | |||
|---|---|---|---|---|---|---|---|---|
| SED 1.2 | 1.20 | 3/4'' | 220/1/50 | 16 bar | GF1.2 + CF1.2 | |||
| SED 2.0 | 2.00 | 1'' | 220/1/50 | 16 bar | GF2.0+CF2.0 | |||
| SED 2.5 | 2.50 | 1'' | 220/1/50 | 16 bar | GF2.5+CF2.5 | |||
| SED 4.0 | 4.00 | 1 1/2'' | 220/1/50 | 16 bar | GF4.0+CF4.0 | |||
| SED 6.0 | 6.00 | 1 1/2'' | 220/1/50 | 16 bar | GD6.0+CF6.0 | |||
| SED 8.0 | 8.00 | 1 1/2'' | 220/1/50 | 16 bar | GF8.0+CF8.0 | |||
| SED 10.0 | 10.00 | 2'' | 380/3/50 | 16 bar | GF10.0+CF10.0 | |||
| SED 13.0 | 13.00 | 2'' | 380/3/50 | 16 bar | GF13.0+CF13.0 | |||
| SED 18.0 | 18.00 | 2 1/2'' | 380/3/50 | 16 bar | GF18.0+CF18.0 | |||
| SED 21.0 | 21.00 | 2 1/2'' | 380/3/50 | 16 bar | GF21.0+CF21.0 | |||
| SED 24.0 | 24.00 | 3'' | 380/3/50 | 16 bar | GF24.0+CF24.0 | |||
| SED 32.0 | 32.00 | 4'' | 380/3/50 | 16 bar | GF32.0+CF32.0 | |||
| SED 44.0 | 44.00 | 4'' | 380/3/50 | 16 bar | GF44.0+CF44.0 | |||
| SED 52.0 | 52.00 | 4'' | 380/3/50 | 16 bar | GF52.0+CF52.0 | |||
| SED 65.0 | 65.00 | 4'' | 380/3/50 | 16 bar | GF65.0+CF65.0 | |||
| SED 75.0 | 75.00 | 4'' | 380/3/50 | 16 bar | GF75.0+CF75.0 | |||
| SED 105.0 | 105.00 | 4'' | 380/3/50 | 16 bar | GF105.0+CF105.0 | |||
When operating conditions differ from the reference conditions, dryer capacity is calculated using the factors below.
Actual Capacity = Nominal Capacity × F1 × F2 × F3 × F4| Temperature (°C) | ≤ 30 | 35 | 40 | 45 | 50 | 55 |
|---|---|---|---|---|---|---|
| Factor | 1.11 | 1.00 | 0.81 | 0.67 | 0.55 | 0.45 |
| Pressure (bar) | 4 | 5 | 6 | 7 | 8 | 10 | 12 | 14 | 16 |
|---|---|---|---|---|---|---|---|---|---|
| Factor | 0.77 | 0.86 | 0.93 | 1.00 | 1.05 | 1.14 | 1.21 | 1.27 | 1.33 |
| Temperature (°C) | ≤ 25 | 30 | 35 | 40 | 45 |
|---|---|---|---|---|---|
| Factor | 1.00 | 0.95 | 0.88 | 0.79 | 0.68 |
| Dew Point (°C) | +3 | +5 | +7 | +10 |
|---|---|---|---|---|
| Factor | 1.00 | 1.09 | 1.19 | 1.37 |
Values in orange correspond to the reference condition (factor 1.00).